Part E Building Regulation Compliance |
|
For general floor improvement options see Soundproofing Floors
Flanking Details:
All acoustic floors and walls are susceptible to flanking noise via flanking paths which may need treating, particularly lightweight block walls.
|
| |
Airborne 60dB(-6 Ctr)
Impact 53dB
 |
Construction (Solid Timber Joist):
- 18mm chipboard or FINISHED surface
- 15mm Phonewell® Floating Floor (FFT)
- 18mm chipboard/OSB
- 235mm solid timber joists
- (100mm 10kg min. mineral wool)
- 16mm standard resilient bars
- 2 x 15mm Acoustic Plasterboard
|
|
| |
Airborne 60dB(-7 Ctr)
Impact 55dB

|
Construction (Timber I-Joist):
- 18mm chipboard or FINISHED surface
- 15mm Phonewell® Floating Floor (FFT)
- 18mm chipboard/OSB
- 300mm timber I-Joists
- (100mm 10kg min. mineral wool)
- 16mm standard resilient bars
- 2 x 15mm Acoustic Plasterboard
|
|
| |
Floor and Wall Junction Details
|
|
| |

|
 |
|
| |
Walls Mounted on the Phonewell® Floating Floor
|
|
| |
 |
 |
|
| |
Floor and Wall Assembly (no flanking strips for minimilastic designs)

|
|
| |
Walls
(Min. 50dB with Phonewell® directly to stud on one side only) |
|
For general Wall improvement options see Soundproofing Walls
|
| |

Single Stud Wall
One Phonewell® layer on one side only brings 36dB (Rw, -4Ctr) and an overall reduction of 50dB!
An Airborne reduction
of 60dB+ is achievable when Phonewell is on both sides.
Easy fitting and easy services installation.
|

Twin Stud Wall (50mm min. gap)
One Phonewell® layer to one side only brings 36dB (Rw, -4Ctr) insulation and 1200kg/m3 density. Isolated twin frames are only necessary for acoustically
critical applications. |
|
| |
Decoupled on Resilient Bars
 |
Additional Plasterboard Layer
 |
|
| |
Floors
|
|
| For general floor improvement options see Soundproofing Floors |
| |

The Open Cavity System
For applications not requiring Thermal Cavity Insulation.
For simple retrofitting over the sub-deck
with an unknown cavity.
|

The Thermal Cavity System
For applications requiring additional
Thermal
Cavity Insulation. The standard
first floor
in England. *Tests undertaken with 7mm hard laminate floor covering!
Airborne (Rw + Ctr) |
Impact (Lnw) |
58dB |
60dB |
|
|
| |

|

|
|
| |
The Dual Impact & Airborne System
For applications requiring additional
Impact Insulation down to 56dB (Lnw).
The lower the result the better! |
The Batten System
For applications requiring extensive
sound insulation and ease of fitting services. Phonewell® strips can be laid under the battens to provide dual impact. Note standard inexpensive kiln
dried timber
can be used for the battens. |
|
Ceilings |
| For general Ceiling improvement options see Soundproofing Ceilings |
| |

Retrofitting
Used when retrofitting where access to the floor above is not possible, eg. multi storey apartments. One Phonewell® layer brings 36dB (Rw, -4Ctr)
insulation.
|
|
|