Phonewell Acoustic Insulation by Acara Concepts Unrivalled Acoustic Insulation  
Soundproofing with Phonewell Acoustic Insulation - The Natural Sound Insulation - Phonewell® data sheet

Stockists throughout the UK and Ireland. Contact UsTEL:IRE + 353 (0)1 8409 286UK 07985 195667

The BBA has awarded the Phonewell Sound Insulation their prestigious Agrement certificate for 'fit for purpose' in building construction and has been accepted by NHBC for use in New Build Development with life time longevity.

Home
About Phonewell®
Technical Data
Applications
Soundproofing Walls
Soundproofing Floors
Soundproofing Ceilings
Timber Frame
Steel Studding
Solid Block
Gallery
Soundproofing Tips
Cutting Phonewell®
Finish Surfaces
Flanking Noise
Links
Site Map
Contact us

See us at:

See us and our ecological Soundproofing and thermal insulation products at the EcoShow live at the King's Hall Belfast 8-10 October 2010


     
 

The Floating Floor Solution for Soundproofing a Concrete Floor.

 
  High soundproofing performance and surpasses building regulations while losing minimal room height. This is the Ideal Solution to Soundproofing a Concrete Floor when there is no access to the ceiling below, for higher performance with ceiling access see the Floating Floor Solution with Decoupled Ceiling Below.  
  Soundproofing a concrete floor from above only


Floating Floor Solution (15mm Above)

Application: Building Regulations New Build, Change of Use, Remedial and Refurbishment.
Simple slim solution offering a high performance and absolute minimal loss of living space, where there is only access to the floor above and no access to the ceiling below e.g. in apartment dwellings.

Construction: (Solid / Concrete Floor):
- sacrificial layer or FINISHED surface
- 15mm Phonewell® Sound Insulation
- solid concrete floor

 
 

Materials List (available from our stockists)
- Phonewell® Acoustic Insulation on Floor (1200mm x 800mm x 15mm)
- Phonewell® Eco-Tape

Instructions: (have you considered Flanking Noise?)
Floor
1.
Treat new concrete floors with a damp proof membrane.
2. Ensure the floor is clean, dry and sufficiently level. If required any unevenness can be levelled out with sand, but Phonewell® does have minor correction capabilities.
3. Begin in one corner and lay the Phonewell® boards on the concrete floor, butted tightly up to the perimeter walls.  Do not screw or nail the boards down.
4. Butt each Phonewell® board up tightly to each other, leaving no gaps.  Lay the boards in a brickwork formation.  See Cutting Phonewell®.
5. Install the finished floor surface as per Fitting Floor Finishes over Phonewell®.
6. Fit skirting boards ensuring no contact with the floor – leave a 2mm gap.
7. Consider treating any identified flanking walls with Phonewell®.

 
 
Sound Insulation the Natural Way
The Highest Airborne Sound Reduction Impact Sound Reduction Outstanding at Low Frequencies; Correction Factor Sound Insulation at only 15mm thick